Podsumowanie treści

Strona 1 - WITH PUMP

DIGITALREFRIGERANT LEAK DETECTOR WITH PUMPUSER’S MANUALRLD400Please read this manual carefully and thoroughly before using this product.

Strona 2 - INTRODUCTION

WARRANTY INFORMATIONGeneral Tools & Instruments’ (General’s) RLD400 Digital Refrigerant Leak Detector withPump is warranted to the original purcha

Strona 3

11NOTES_______________________________________________________________________________________________________________________________________________

Strona 4 - KEY FEATURES

GENERAL TOOLS & INSTRUMENTS80 White StreetNew York, NY 10013-3567PHONE (212) 431-6100FAX (212) 431-6499TOLL FREE (800) 697-8665e-mail: sales@gener

Strona 5 - OPERATING INSTRUCTIONS

TABLE OF CONTENTSIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 –4How It Works . . . . . .

Strona 6 - Sensor socket and

WHY LOOK FOR REFRIGERANT LEAKS?There are three reasons to detect and repair leaks of refrigerant gases fromstationary and mobile air conditioners, ref

Strona 7

The digital readout makes it easy to pinpoint the source of a leak and helps you decidewhether it is large enough to be worth plugging. The reading is

Strona 8

WHAT’S IN THE CASEThe RLD400 comes fully assembled in a padded hard plastic carrying case. Also in thecase are a leak test vial (for checking that the

Strona 9 - MAINTENANCE INSTRUCTIONS

IMPORTANT: The startup sequence will not execute to completion if the refrigerant gassensor cannot be heated. That would be the case if the sensor be

Strona 10 - RETURN FOR REPAIR POLICY

The reading reflects the concentration of refrigerant gas sensed. The maximum valuewill be displayed when the tip of the probe is at the source of the

Strona 11

USING THE LEAK TEST VIALThe RLD400 ships with a leak test vial that lets you check whether the instrument isworking properly. To perform this check:1)

Strona 12 - TOLL FREE (800) 697-8665

SPECIFICATIONSRefrigerants Detected R-134a, R-410a, R-404a, R-407c, R-507, CFC-12 (R-12 or Freon), R-22, R-1234yfDetection Modalities Sound, light, le