General-tools-and-instruments CIH20DL Instrukcja Użytkownika Strona 13

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 12
Fig. 8. The Advanced Settings Menu
13
Normal Measuring
mode
Air Speed or Airflow
Volume mode
Air speed unit
Airflow
volume unit
Temperature unit
Enter area of
grille or register
Sampling time of
data log
Clear data
logging memory
Set current date
Set current time
Press and hold the MODE SET button for 3+ seconds to enter/exit
menu from/to normal measuring mode.
Press the
or
button to select CMM, CFM (for Airflow Volume
mode) or m/s, ft/min, km/h, mile/h, knots (for Air Speed mode).
When your choice flashes, press the MODE SET button to store it.
Press the
or
button to select m/s, ft/min, km/h, mile/h or knots.
When your choice flashes, press the MODE SET button to store it.
Press the
or
button to select CMM or CFM. When your choice
flashes, press the MODE SET button to store it.
Press the
or
button to select °F or °C. When your choice
flashes, press the MODE SET button to store it.
Use the button to toggle between the minutes and seconds fields of
the time shown on the secondary readout. Use the
and
buttons
(holding them, if convenient) to adjust the flashing value within each
field. The sampling time can be set to any value between 5 seconds
(00:00:05) and 59 minutes, 59 seconds (00:59:59). After entering the
desired sampling time, press the MODE SET button to store it.
TempIR
Press the button to clear the meter’s internal data logging memory.
Doing so resets the five-digit Memory Space counter and causes it
and the text CLR-Memory above it to flash, confirming the erasure.
After six seconds, the meter will automatically exit the Advanced
Settings Menu and enter normal measuring mode.
TempIR
Use the button to toggle between the year, month and day fields of
the date shown on the secondary readout. Use the
and
buttons
(holding them, if convenient) to adjust the flashing value within each
field. After entering the current date, press the MODE SET button to
store it.
TempIR
Use the button to toggle between the hours, minutes and seconds
fields of the time shown on the secondary readout. Use the
and
buttons (holding them, if convenient) to adjust the flashing value
within each field. Remember to use the 24-hour format when setting
the hour. After entering the current time, press the MODE SET button
to store it.
TempIR
Press (and hold, if convenient) the
or
button to adjust the value
on the primary readout to the measured area. The area can be
adjusted from 0.01 to 322.92 ft
2
in increments of 0.01 ft
2
, or from
0.001 to 30m
2
in increments of 0.001 m
2
. After entering the correct
area, press the MODE SET button to store it.